TOHO ELECTRONICS INC.
Multi-Channel Board Controller
Detailed Manual
Thank you very much for purchasing a Multi-Channel Board Controller.
The Multi-Channel Board Controller outputs control signals that match an input from
a thermocouple (a K/J thermocouple) or an input from a temperature input from a
resistance bulb (Pt100/JPt100) to a predetermined setting.
The product comes equipped with an RS-485 or an RS-232C for data
communications with a host computer.
For control output, the product is provided with up to eight open collector outputs,
along with event outputs consisting of 11 open collector outputs (eight temperature
alarm outputs, one heater wire break alarm, one SSR breakdown alarm, and one error
alarm), eight current detector inputs, and one voltage input.
Please read this detailed manual carefully and use this product correctly.
Vue de la page 0
1 2 3 4 5 6 ... 34 35

Résumé du contenu

Page 1 - Detailed Manual

1 TOHO ELECTRONICS INC. Multi-Channel Board Controller Detailed Manual Thank you very much for purchasing a Multi-Channel Board Controller.

Page 2

10 Parameter a) Identifier b) Name c) R/W d) Description and set range e) Remark Initial value (communication numerical data) TC, thermocouple

Page 3 - Warnings

11 Event output parameters a) Identifier b) Name c) R/W d) Description and set range e) Remark Initial value (communication numerical data) TC

Page 4 - 2.2 Names and functions

12 Voltage input parameters a) Identifier b) Name c) R/W d) Description and set range e) Remark Initial value (communication numerical data) T

Page 5 - 3. Installation

13 Monitor window parameters a) Identifier b) Name c) R/W d) Description and set range e) Remark PV1 Measurement R Used as a measurem

Page 6 - 4. Making the connections

14 Control parameters a) Identifier b) Name c) R/W d) Description and set range e) Remark Initial value (communication numerical data) TC, the

Page 7 - 4.2 Terminal arrangement

15 Control parameters a) Identifier b) Name c) R/W d) Description and set range e) Remark Initial value (communication numerical data) TC, therm

Page 8

16 7. Function description 7.1 Display range and set range of temperature input 7.1.1 Display range and set range of thermocouple input (JIS C

Page 9 - Warning

17 7.5 Temperature alarm output 7.5.1 Temperature alarm output: Compare the measurements with the setting value of the temperature alarm output an

Page 10 - Parameter

18 7.6 Heater wire break alarm output The output will be turned on if a heater wire break (no output even if the output is turned on) remains for a

Page 11 - Event output parameters

19 7.9.3 Communications procedure This product returns a "response message" in response to a "request message" from a high-leve

Page 12 - Unit common parameters

2 Contents 1. Operating precautions ... 3 2

Page 13 - Monitor window parameters

20 7.9.5 Composition of a request message (transmitted from a high-level computer to this product) n For codes ① to ⑧, see "7.9.9 Code desc

Page 14 - Control parameters

21 7.9.6 Composition of a response message (transmitted from this product to a high-level computer) n For codes ① to ⑪, see "7.9.9 Code des

Page 15

22 7.9.7 Composition of a memory bank function message n For codes ① to ⑫, see "7.9.9 Code description." n For specific examples of r

Page 16 - 7. Function description

23 7.9.8 Setting and reading data collectively 1) Composition of a read request message a) All channels S T X □ A R □ □ □ E T X B C C ① ② ③ ④ ―⑤―

Page 17

24 7.9.9 Code description n Codes from ① STX to ⑫ memory bank function are expressed in ASCII codes. n For the ASCII codes, see "7.9.13.

Page 18 - 7.8 Error alarm output

25 ⑧ BCC This is a check code for error detection and is the exclusive OR (EX-OR) of all characters from STX to ETX. ⑨ ACK It is an acknowl

Page 19 - 7.9.4 Message types

26 7.9.10 Communications precautions 1) Communications timing Set a sufficient response delay to make sure that this product is switched over

Page 20

27 8) Storing data other than a store request message Store all parameters in the EEPROM in either of the three cases described below, even if no

Page 21

28 7.9.12 Examples of communications to be written Example: Request message: Requests that the temperature alarm output setting of EIF in channel 1

Page 22

29 7.9.13 Table of ASCII codes ASCII code 02H 03H 06H 15H Code used STX ETX ACK NAK ASCII code 30H 31H 32H 33H

Page 23

3 1. Operating precautions When the product reaches you, please ensure that the product you have received is of the following model which you order

Page 24 - 7.9.9 Code description

30 4) Character : Start bit length... Fixed at 1 bit : Stop bit length ... Fixed at 2 bit : Data length...

Page 25

31 7.9.15 Communication wiring 1) Connecting the RS-485 line T/R(A)T/R(B)T/R(A)T/R(B)T/R(A)T/R(B)T/R(A)T/R(B)上位コンピュータ(親局) 本器(子局)本器(子局)本器(子局) I

Page 26

32 8. Specifications and ratings 8.1 General specifications Power voltage 24V DC + 10% - 15% Power consumption 8W or less Insulation resistanc

Page 27

33 9. Maintenance and inspection Symptom Check item Inaccurate measurement Is the sensor normal? (Connect a different sensor to the line. Does

Page 28

34 TOHO ELECTRONICS INC. Head office: 1-13-21, Tanashioda, Sagamihara Kanagawa 229-1125 Japan. Phone: +81

Page 30

4 2. Names and functions of the components 2.1 Product diagram Event output Control output CT input Voltage input Communi- cation Power Tempe

Page 31

5 2.2.9 TB4: Voltage input terminal Voltage input terminal (input voltage range: 12 to 24V DC ±10%) Through-type terminal block: ML-40-S1BYF-2P

Page 32

6 3.3 Outside dimensions 4. Making the connections 4.1 Terminal arrangement diagram 4.1.1 Thermocouple input Board height • Thermocouple

Page 33

7 4.1.2 Resistance bulb input 4.2 Terminal arrangement 4.2.1 Temperature input (TB1: terminal block): For thermocouple input * For terminal

Page 34

8 4.2.5 Voltage input (TB4: terminal block) Terminal No. Polarity 1 + 2 − 4.2.6 Control output (CN1: connector) Connector No. CH Terminal name 1

Page 35

9 4.3 Cautions on making the connections Warning • Before making the connections, turn off this product. Otherwise you may get an electrical sho