TOHO ELECTRONICS INC.
MANUALBOARD TYPE DIGITAL CONTROLLER SERIES INSTRUCTION
TTM-10L
Thank you for purchasing model TTM-10L series Digital Process Controller.
Please go through this Instruction Manual carefully and use the unit in proper manner.
NOTICE/WARNING BEFORE USAGE
1.
・When having the controller in hand,please confirm the correct model and optional function for
your purchase. Please refer to ”8. ORDERING INFORMATION” for details of model.
・The following symbol marks are used in this Instruction Manual for handling this model safely.
In case of mishandling, serious dangers may occur to the
WARNING
operator such as death, electrocution and a skin burn.
In case of mishandling, it may cause some damages to the
CAUTION
unit or the operator getting slight injury.
CAUTION WARNING
・Do not push the keys by sharp points Make sure the correct wiring connection before turning on electricity.
for prevention of its malfunction. Mis-wiring may cause malfunction of the unit and may cause a fire.
・Never remodel the unit to prevent malfunction of unit and fire.
PARTS INDICATION
2.
2.1 OPERATION KEYS a) W1:MODE key.・・・・・Change Each Mode/Parameter.
b) W2:Up key ・・・・・Up Setting Value or Change setting.
c) W3:Down key ・・・・・Down Setting Value or Change setting.
OUTER DIMENSIONS
3.
3.1 OUTER DIMENSIONS
3.2 LOCATION OF THE UNIT SETTING
Install the unit at the following proper locations:-
a)Away from the gas of sulfide and corrosion. h)Less dust and oily smoke.
b)Less mechanical vibration and shock. i)Away from the direct dampness or the flood with water.
c)Temperature and Humidity being within the limit of operation environment.
d)Away from the direct sunshine and not to be exposed by wind and rain.
e)Far away from the equipments using high-voltage ignition devices.
f)Away from the influence of electromagnetic field.
g)Away from High-Voltage wire, welding machine and the generator of electric noise.
WIRING METHOD
4.
4.1 SocketCHANGE OF POWER SUPPLY.
with the Terminal BlocksThe change of Power supply is available to select
following plugs a,b and c.
←1PIN
:Short circuit socket fixed to a and b.:12VDC
:Short circuit socket fixed to b and c.:24VDC
Plug a b c
Board
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - CAUTION WARNING

TOHO ELECTRONICS INC.MANUALBOARD TYPE DIGITAL CONTROLLER SERIES INSTRUCTIONTTM-10LThank you for purchasing model TTM-10L series Digital Process Contro

Page 2 - ①②③④⑤⑥⑦⑧⑨⑩⑪⑫

4.2 TERMINAL CONNECTION DRAWING4.3 CAUTION FOR WIRING CONNECTIONWiring material with resistance less than 5 per wire should be used to connect R.T.D.

Page 3

5.3 OTHER DISPLAY INDICATIONSShown whenever Input value exceeds the High limit of Display range, or the snapping of the Input line.6666:Shown whenever

Page 4

For Thermocouple Input Shown at all cases.80SV Limiter Setting range: Full scale range of SV, but the differencewith should be more than 50 ( F).Low (

Page 5

Displays [email protected] ●◆ ▲tionparameter ●BCC CHECK ◆DATA PARITY ▲STOPLENGTH BIT7NoneE7 BITS7None 19YesA8 BITS(odd Number 29A7"E

Page 6

DEFINITIONS AND FUNCTIONS7777....ADDITIONAL FUNCTIONS7.1Stand-by Sequence This is the function not to turn on Alarm Output even if it covers the condi

Page 7

ORDERING INFORMATION8888....TTM−10L−□−□−A□記号 記号 記号Input Output Option0 N Communication M1Thermocouple / R.T.D. None4∼ 20mADC 1 R RS−485Relay contactP

Page 8 - TOHO ELECTRONICS INC

TOHO ELECTRONICS INC.TOHO ELECTRONICS INC.TOHO ELECTRONICS INC.TOHO ELECTRONICS INC.Head office : 10213−23,Tana,Sagamihara Kanagawa 229-1124 Japan.Pho

Commentaires sur ces manuels

Pas de commentaire