48-7009-E 6-76
Wait Range Setting
PGF
Setting Contents
Initial
Value
5
Wait Range Setting 3
2
During Temperature Input
Soak Time 1
0999009999
Soak Time 2
0999009999
During H/MP(Soak Time 2)the behavior will
be identical to that of (Soak Time 1) with Setting=0
During Analog Input
Soak Time 1
09999digit
Soak Time 2
09999digit
During H/MP(Soak Time 2)the behavior will
be identical to that of (Soak Time 1) with Setting=0
5 WAIT RANGE SETTING (WAIt)
Time Unit Setting (H/MP) sets the condition of countdown (Range against PV Value) during the setting of
(Soak Time 1) (Soak Time 2).
Please refer to Time Unit Setting (H/MP) for the explanation of its action.
Setting Range
(During Temp. Input)
Soak Time 1: 0 to 999 (0.0 to 999.9)
Soak Time 2: 0 to 999 (0.1 to 999.9)
(During Analog Input)
Soak Time 1: 0 to 9999 (digit)
Soak Time 2: 0 to 9999 (digit)
NOTE: RE: Behavior during WAIT Range Setting (Setting Value = 0)
Even if the H/MP (Soak Time 2) is being set, when the Setting Value = 0, the behavior would be the same as that of (Soak
Time 1).
NOTE: Regarding the AT (Auto-Tuning) behavior during the program in operation.
The AT can be done while the program is in operation. The SV Value which operates the AT is the SV* (Step SV) Value that is set in
each steps. Also, this condition applies also during RMP in operation with set RMP movement.