48-7009-E 5-5
When setting the digit shift function by assigning it on the FUNC key
Content of the function of the function key
* The function key (FUNC) is set on the digit shift function in this screen.
Use the / key to change 00 to *1.
The symbol * represents the item to be designated for time for which the
function key (FUNC) is held pressed.
0: None, 1: 1 second, 2: 2 seconds, 3: 3 seconds, 4: 4 seconds and 5: 5 seconds
* Example for setting: 11 indicates that holding the FUNC key pressed for 1
second enables it effective.
* Holding the MODE key pressed for 2 seconds moves each setting screen to the operating mode screen.
* In about 2 minutes, each setting screen (or any setting screen) automatically moves back to the
operating mode screen.
Continued to the next page
Initial screen
4 seconds
Input 1 setting screen
Hold MODE key
pressed for 2 seconds.
Press the key twice.
Press it, however, once for TTM-204.
Hold MODE key pressed for 2 seconds.
Power-on
4 seconds
Hold MODE key
pressed for 2 seconds.
Key function setting screen
Press MODE key once.
S03-1 Function key 1 function setting screen
SET 21 program mode setting
A (C/P 0) constant value
run mode is established.
SET 21 program mode setting
A (C/P 0) program run
mode is established.
For constant value run mode screen:
Measurement value
(PV)
Target value (SV):
Set to 0 at factory
shipment
For program run mode screen:
PV value (present value)
SV value (PRoG)
Hereinafter, to the input 1 setting
screen similarly to that for the
constant value run mode
Vue de la page 74