Toho-electronics TTM200 Manuel d'utilisateur Page 43

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 264
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 42
48-7009-E 4-2
4.1 Flow of setting mode
PROG
25
0
25
0
INP1
The equipment does not operate for
about 4 seconds after power-on.
At SET 21 program mode setting
In (C/P = 0) constant value run mode
Power-on
Initial screen
Constant value run mode screen
4 seconds
4 seconds
At SET 21 program mode setting
In (C/P 0) program run mode
Program run mode screen
The following is possible in this mode: display of PV value
(present value), setting of SV value (setting value) which is
the target value of control, display of remaining time
monitor for timer 1, 2 and 3, display of priority screens 1 to
16, display of the bank No. that is presently set and various
functions in effect (output, CT, communication, DI, AI, etc.)
The following is possible in this mode: display of PV
value (present value), program run status for SV value,
display of remaining time monitor for timer 1, 2 and 3,
display of priority screens 1 to 16, display of the bank
No. that is presently set and various functions in effect
(output, CT, communication, DI, AI, etc.)
MODE key for
2 seconds
At SET 21 program mode setting
Transition is made one another
according to the C/P setting.
MODE key for
2 seconds
Setting item selection screen (SET 01 - SET 23) (See the page 6-1 and thereafter.)
Various parameters regarding SET 01 - SET 23 are set.
SET 21 and 22 are settings for the program run.
MODE key
Parameter setting screen in each SET
Various parameters are set. (See pages 6-2 to 6-xx.)
* Using the MODE key, parameter screens for each setting mode is displayed in sequence, and the screen
returns to the SET** screen.
* Using the / key, the setting item selection screens SET 01 to SET 23 is displayed in sequence.
(In case of no function registered, the corresponding screen is not displayed.)
(For program run mode, see pages 6-13 to 6-xx.)
* The screen moves back to the operating mode screen when holding the MODE key pressed for 2 seconds in
parameter screens for each SET screen.
Blind setting screen
The screen for setting items to be blinded
(non-displayed) by using parameters appears.
For details, see pages 4-27 and 28.
MODE key for
10 seconds
MODE key for
10 seconds
No key operation for about 2 minutes automatically moves the screen back to the operating mode screen.
If a function is not specified, corresponding SET screen is not displayed.
Holding the MODE key pressed for at least 2 seconds moves the setting item selection screen back to the
operating mode screen or vice versa.
Use the / key to move the parameter setting screens.
Use the MODE key to move each parameter setting screen.
Vue de la page 42
1 2 ... 38 39 40 41 42 43 44 45 46 47 48 ... 263 264

Commentaires sur ces manuels

Pas de commentaire