Toho-electronics TTM200 Manuel d'utilisateur Page 85

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 264
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 84
48-7009-E 5-15
5.3.5 Indicator setting
Setting as an indicator
Blinding the target value (SV) enables to use the screen as an indicator.
Hold MODE key pressed for 10 seconds.
Constant value run mode screen
PV value (present value)
SV value (target value)
Input 1 setting screen
Each set screen
Each setting mode
PV/SV blind setting screen
* Use the FUNC key for its setting.
In a blind state, characters in the lower row (red) are not displayed.
(Pressing the FUNC key results in displaying “PVSV,” “PV,” “SV” and “PVSV” in
sequence.)
Pressing once the FUNC key displays only characters of “PV” in the lower row (red).
By turning the power off and back on, or holding the MODE key pressed for about
10 seconds in this state, only the upper row (green) is displayed.
The above operations determine the blind-setting of the target value (SV).
Setting for no provision of outputs is conducted next.
Constant value run mode screen
Hold MODE key pressed for 2 seconds.
PV value (present value)
SV value (target value)
Input 1 setting screen
Each set screen
Each setting mode
Press the key three times. Press it, however, twice for TTM-204.
Continued to the next page
Hold MODE key pressed for 2 seconds.
When blinks, press the FUNC key, and then press the MODE key.
Vue de la page 84